Important for handover: This article covers the start of the configuration. To hand over the installation to the customer completely, commissioning must then be completed via the reev Companion.
Supported models
The following Alpitronic HyperCharger models are supported:
HyperCharger HYC50
HyperCharger HYC150
HyperCharger HYC300
HyperCharger HYC400
These instructions are specific to firmware version 3.1.x or higher. For charging stations with older firmware, see this guide.
Prerequisites
Required materials
Laptop with RJ45 data cable to connect to the charging station's control unit
Active internet connection via Ethernet or Wi-Fi
Note: Make sure the charging station runs the latest firmware version from Alpitronic before you start the configuration. You can find out which version is current directly from the manufacturer.
Configuring the Alpitronic user interface
Connecting to the charging station
To connect to the charging station and access the user interface:
Insert the SIM card into the Client SIM slot of the charging station.
Connect the laptop to the charging station with an RJ45 data cable.
Open the web interface in your browser using the default IP address 192.168.1.100.
Log in with the supplied credentials:
Username: admin
Password: admin123
Note: If the password "admin123" does not work, the default password is the MAC address of the charging station.
Note: Make sure you use the Client SIM slot, not the Server SIM slot.
After a successful connection, you are on the charging station's user interface.
Step 1 – Check the firmware version
Before making any configuration changes, check the installed firmware version of the charging station.
Navigate to Software Versions.
Check whether the latest firmware version is installed. You can find out which version is current directly from the manufacturer.
If the firmware is up to date, continue with Step 2.
If the firmware is not up to date, perform the update before continuing.
Step 2 – OCPP configuration
To configure the OCPP connection:
Navigate to Parameters.
The following parameters should be changed:
Field | Value |
chargePointIdentity | Individual name of the charging station (no special characters except "_") |
ActiveOcppVersion | ocpp1.6 |
WebSocketUrl | wss://ocpp.reev.com |
Use the search bar to quickly find specific parameters. Please click the floppy disk icon to save after each change.
Example: The chargePointIdentity can be assigned as follows:
HYC_150_22BZ0660A22BZ0660AAlpitronic_22BZ0660A
Step 3 – Network configuration
3.1 Ethernet configuration
To configure the Ethernet connection:
Navigate to Network.
Select Wired as the Preferred Network.
Enter the Static IP Address, the Subnetmask and the Default Gateway.
Delete the entries for Primary DNS and Secondary DNS – but only if the reev SIM card is used for the connection.
Click Save .
Note: Ask the on-site IT administrator for the correct IP address settings. We recommend assigning static IP addresses so that local access to the web interface is ensured even during a network outage.
3.2 SIM configuration
To configure the APN settings:
Navigate to Network Settings -> SIM.
Enter the following values:
Field | Value |
SIM PIN | Not required (can optionally be entered) |
APN | emonvia |
Authentication | NO APN Authentication Required (deactivate) |
Provider Selection
| Automatic Selection (activate if not already active) |
Click the floppy disk icon to save.
3.3 Preferred network
To set the preferred network:
Navigate to Network.
Under Preferred Network, select Mobile or Wired, depending on the connection.
Step 4 – Perform a system reboot
To restart the charging station after configuration:
Click Hard Reset in the upper right corner to restart the charging station.
Note: The restart of the charging station takes approx. 10 minutes. Afterwards, the SIM card searches for a mobile network and connects to it. This process can also take up to 10 minutes.
To check whether the SIM card has connected successfully:
Navigate to Status -> SIM.
Check whether an active mobile connection is displayed.
Commissioning with the reev Companion
Once the charging station has been configured successfully, it can be commissioned via the reev Companion.
Frequently asked questions
Which firmware version must be installed on the charging station? The charging station must run the latest firmware version from Alpitronic. You can find out which version is current directly from the manufacturer.
What if the default password "admin123" does not work? In this case, the default password is the MAC address of the charging station. It is usually on the type plate of the station.
Which SIM slot must I use? Use only the Client SIM slot. The Server SIM slot is not intended for this configuration.
Why should I assign static IP addresses? Static IP addresses ensure that local access to the web interface is retained even during a network outage. Ask the on-site IT administrator for the correct settings.
How long does the system reset take? The restart of the charging station takes approx. 10 minutes. The subsequent connection of the SIM card to the mobile network can take up to a further 10 minutes.